Please use this identifier to cite or link to this item: http://148.72.244.84:8080/xmlui/handle/xmlui/6412
Title: Determination of Zinc Ions in Drinking Water Distribution Systems (PVC pipes) by Spectrophotometric Method
Authors: Fatma H Abdulla
Keywords: Keywords: spectrophotometric, PVC pipe, zincon, drinking water
Issue Date: 2016
Publisher: University of Diyala
Abstract: In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different concentrations of zinc were used to check the prediction ability of the complexation. Water quality samples collected a 100cm PVC system of drinking water in three sizes from different country full with deionized water for different time
URI: http://148.72.244.84:8080/xmlui/handle/xmlui/6412
ISSN: 2222-8373
Appears in Collections:مجلة ديالى للعلوم الاكاديمية / Academic Science Journal (Acad. Sci. J.)

Files in This Item:
File Description SizeFormat 
4.pdf672.38 kBAdobe PDFView/Open