Abstract:
ABSTRACT
Composite bridge consists of different materials such as the girder
made of steel or precast that connected with deck concrete slab by means of
shear connectors to work as one. In the present study, AL-SABTEA
composite bridge in Diyala, Iraq that was designed and constructed
inherently to work as full interaction. The interior composite concrete steel
girder is selected as a case study because it represents the worst case.
Representation of composite steel bridge throughout the present study was
done using finite elements approach by ANSYS software with different
parameters to assess the efficiency of the composite bridge under the effects
of static based on Iraqi and AASHTO specifications as well as dynamic and
fatigue loading according to AASHTO specification using actual
dimensions and mechanical properties.
Push-out test was also done to compare displacement results with the
model established by ANSYS which proved that the proposed numerical
model can represent the shear connector's behavior. It is recognized that the
difference in the results of displacement of the latter comparison is small
(5%) between experimental test and ANSYS model.
The effect modelling of shear connector was studied by the
representation of channel shear connectors through elements of COMBIN39
element in comparison with using solid elements. The deflection difference
between these two models is also small (2.5% to 3.7%).The results showed that the deflection and stresses according to the
Iraqi specification are more than AASHTO specification but still within
permissible safe limits, furthermore, dynamic analysis which was done with
different truck loading and velocity speed showed that truck HS20 gives
deflection and stresses more than other trucks. In addition, as the velocity
increases, the deflection and stresses under the effect of a specific load
increase, due to increase in kinetic energy.
The fatigue analysis results indicated that the damage index at top face
of the concrete deck slab, interface between concrete and steel girder and at
bottom of steel flange girder for all load cases do not reach to unity and the
maximum value is less than 0.2% in the case of HS20 loading. The fatigue
damage at present time for Al-SEBTEA bridge if checked by adopting any
methodology do not also reach 0.0045 for 10 years. The worst case of
analysis result indicated that the maximum damage index occurs in the
bottom face of composite steel girder that represent accumulative fatigue at
this point.
Visual basic code was written as analytical solutions to calculate the
number of shear connectors under the effects of static and fatigue loadings
and also estimate the number of cycles during the bridge life. The
relationship between the fatigue stress with stress ratio appeared as the
fatigue stress increase when the stress ratio increase in a positive direction
. The fatigue stress increases with
the decrease in reverse stress ratio in the range of (-1) up to zero in case of
R=0.
In final assessment the results of deflection and stresses and fatigue
stress within permissible are limited according to AASHTO code for all
models.