Please use this identifier to cite or link to this item: http://148.72.244.84:8080/xmlui/handle/xmlui/8784
Title: Sensitivity and Specificity of Phalen’s Test and Tinel’s Test in Patients with Carpal Tunnel Syndrome
Authors: Khalid A.O.Al-Dabbagh
Shorsh Ahmad Mohamad
Keywords: Carpal Tunnel Syndrome (CTS)
Phalen Tinel tests
Issue Date: أكت-2013
Publisher: University of Diyala - College of Medicine
Series/Report no.: Vol 5;Issue 1
Abstract: Background: Carpal Tunnel syndrome (CTS) is the most common cause of paraesthesia in the hands and it is the most common entrapment neuropathy in the upper and lower limbs. The symptoms are variable, but episodes of burning pain or tingling in the hand are common. Diagnosis of CTS is mainly clinical based on suggestive history and Physical examination. Several physical signs are associated with carpal tunnel syndrome, including Tinel’s test and Phalen’s test. Objectives: of this study are to determine the sensitivity and specificity of the Phalen΄s and Tinnel΄s tests in the diagnosis of Carpal Tunnel Syndrome and to analyze how such factors as patients age and duration of symptoms influence these parameters. Patient &Methods: This is a prospective study comparing two groups (patient and control). One hundred cases (90 females and 10 males), who fulfilled the National Institute of Occupational Safety and Health (NIOSH) criteria for diagnosis of CTS attending physiotherapy unit in Rizgary Teaching Hospital in Erbil-Iraq .The control group included (90 females and 10 males) who were healthy asymptomatic volunteer .The duration of the study was eight months from 1st may 2011to 1st February 2012. Both groups were assessed by Phalen and Tinel tests. Result: within patient group 78(78%)cases were having positive phalen and 66(66%) cases had positive tinel test while in the control group 6 (6%) were having positive phalen and 23(23%) controls had positive tinel test. The resulting specificity and sensitivity of Phalen test for the patient and control groups were 94% and 78%respectively while specificity and sensitivity of Tinel test were 77% and 66% respectively. There is also a significant association between duration of symptoms less than 6 years and Tinel test results. Conclusion: Phalen test is more specific and sensitive than Tinel test so it is essential in the diagnosis of CTS particularly when the Nerve Conductive Study (NCS) is not available
URI: https://djm.uodiyala.edu.iq/index.php/djm
http://148.72.244.84:8080/xmlui/handle/xmlui/8784
ISSN: Print ISSN 2219-9764
Online ISSN 2617-8982
Appears in Collections:مجلة ديالى الطبية / Diyala Journal of Medicine

Files in This Item:
File Description SizeFormat 
1-Dr.Khalid Al.Dabbagh.pdf654.95 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.